If the thermostat is
displaying 'CODE', initially you will ONLY be presented with step 1 and
step 4, set these as described below.
Once you have either
completed steps 1 and 4, or the controller is displaying something other
than 'CODE', you must press and hold the button until the word
'CODE' is displayed and follow the steps below:
Step
1 - Setup Code
Rotate
button to select code 0044 and then press button once.
Step
2 - Operating Mode
Rotate
button to select 'ALO' and the press button.
Step
3 - Temperature Readout
Rotate
button to select °C and then press button.
Step
4 - Sensor Selection
Mat
systems:- Rotate
button to select 'FS' (not rFs or rs) to activate the floor
sensor, then press button. Reading will not show temperature scale
only 1-10
Cable systems select rFs. Temperature
scale will be shown.
Step
5 - Maximum Floor Temperature
At
'nt' rotate button to select either of the following maximum floor
temperatures, then pres button.
Tiles
on timber based floors 27°C - 31°C
Tiles
on concrete based floors 40°C
Timber
covered floors(laminate etc.) 27°C
Step
6 - Off Periods
'LO'
should be displayed, you should rotate dial to select -15°C, then
press button.
Step
7 - Clock Display
Rotate
button to select clock display as either 24 hours or 12 hours
AM/PM.
Step
8 - Save Settings
Press
button once.
If the
controller is now displaying CODE, disconnect the power to the
controller and then reconnect